Vacon Option Modules

VaconOption modules:
The following option modules can be added to the Vacon series drives.
*Note that not all modules are compatible will all drive versions, please contact us for confirmation of compatibility.

Vacon 100 series general information about option boards General info for Vacon 100 option boards
OPT-F3-V Standard I/O board: 2 x AI, 6 x DI, 1 x AO, 10 Vref, 24 Vin, 2 x 24 Vout, RS485, 3 x RO OPT-F3 manual
OPT-F4-V Optional I/O board: 2 x AI, 6 x DI, 1 x AO, 10 Vref, 24 Vin, 2 x 24 Vout, RS485,2 x RO, Thermistor input OPT-F3 manual
OPT-B1-V 6 x DI / DO, programmable OPT-B1 manual
OPT-B2-V 2 x RO, Thermistor input OPT-B2 manual
OPT-B4-V 1 x AI, 2 x AO (isolated) OPT-B4 manual
OPT-B5-V 3 x RO OPT-B5 manual
OPT-B9-V 1 x RO, 5 x DI (42-240 VAC) OPT-B9 manual
OPT-BF-V 1 x AO, 1 x DO, 1 x RO OPT-BF manual
OPT-BH-V 3 x Temp sensor inputs (PT100, PT1000, KTY84-130, TY84-150, KTY84-131, NI1000) OPT-BH manual
OPT-C4-V LonWorks OPT-C4 manual
OPT-E3-V PROFIBUS DPV1 OPT-E3 manual
OPT-E5-V PROFIBUS DPV1 (D9) OPT-E3 manual
OPT-E6-V CANopen OPT-E6 manual
OPT-E7-V DeviceNet OPT-E7 manual
OPT-EC-V EtherCAT OPT-EC manual
OPT-BJ-V Safe Torque Off (STO) / Safe Stop 1 (SS1) / ATEX OPT-BJ manual
Vacon NX options:
Vacon NX series general information about option boards General info for Vacon NX option boards
OPT-A1 Main board, 6 x DI, 1 x DO, 2 x AI, 1 x AO OPT-A1 manual
OPT-A2 Main board, 6 x DI OPT-A2 manual
OPT-A3 IO board, 1 x RO (NO/NC), 1 x TI (thermistor input) OPT-A3 manual
OPT-A4 3 DI encoder (RS-422) + 2 DI (qualifier & fast input) OPT-A4 manual
OPT-A5 3 DI encoder (wide range) + 2 DI (qualifier & fast input) OPT-A5 manual
OPT-A7 6 DI encoder, 2 DO encoder OPT-A7 manual
OPT-A8 IO board, 6 x DI, 1 x DO, 2 x AI, 1 x AO OPT-A8 manual
OPT-AE 3 DI encoder (wide range), 2 DO (Enc.) OPT-AE manual
OPT-AK Sin-Cos option board OPT-AK manual
OPT-AL Six 42…240 VAC digital inputs, 2 analog inputs,two analog outputs, one digital output and 15 and 24 V out. OPT-AL manual
OPT-AN IO board, 6 x DI, 2 x AI, 2, AO OPT-AN manual
OPT-B1 IO board, 6 x DI, 6 x DO OPT-B1 manual
OPT-B2 IO board, 1 x TI (thermistor input), 2 x RO OPT-B2 manual
OPT-B4 IO board, 1 x AI (isolated), 2 x AO (isolated) OPT-B4 manual
OPT-B5 IO board, 3 x RO OPT-B5 manual
OPT-B8 3 x Pt-100 OPT-B8 manual
OPT-B9 IO board, 1 x RO, 5 x 42-240VAC inputs OPT-B9 manual
OPT-BC Resolver OPT-BC manual
OPT-BE Endat/SSI option board OPT-BE manual
OPT-BH Temp measurement board – PT100, PT1000, NI1000, KTY84-130, KTY84-150, KTY84-131 OPT-BH manual
OPT-BB Absolute encoder board – Endat type encoder OPT-BB manual
OPT-BJ STO and ATEX option board OPT-BJ manual
OPT-C2 RS-485 (Multiprotocol) OPT-C2 manual
OPT-C3 Profibus DP OPT-C3 manual
OPT-C4 LonWorks OPT-C4 manual
OPT-C5 Profibus DP (D9-type connector) OPT-C3 manual
OPT-C6 CANopen (slave) OPT-C6 manual
OPT-C7 DeviceNet OPT-C7 manual
OPT-C8 RS-485 (Multiprotocol, D9-type connector) OPT-C8 manual
OPT-CG SELMA 2 protocol OPT-CG manual
OPT-CI Modbus/TCP (Ethernet) OPT-CI manual
OPT-CJ BACNet, RS485 OPT-CJ manual
OPT-CP ProfiNet I/O (Ethernet) OPT-CP manual
OPT-CQ Ethernet/IP (Ethernet) OPT-CQ manual
OPT-D1 System Bus adapter (2 x fiber optic pairs) OPT-D1 manual
OPT-D2 System Bus adapter (1 x fiber optic pair) & CAN-bus adapter (galvanically decoupled) OPT-D2 manual
OPT-D3 RS232 adapter card (galvanically decoupled), used mainly for application engineering to connect another keypad OPT-D3 manual
OPT-D6 CAN-bus adapter (galvanically decoupled) OPT-D6 manual

Vacon Option Modules